Three-phase AC 50Hz, rated voltage of 1 2kV fixed installed indoor switchgear. Mainly used in power plants, substations and distribution system control and protection, but also to ring network for distribution, load-breaking important and frequent operation place.
operation: manually, but also electrical
Electric power operation: AC 220V, DC 110V
Anti-jump and latch, over-current release, such as loss of pressure release device and the second matching circuit to optimize the design of reliable and safe for the circuit breaker to provide a strong operational security, as well as users in the protection and intelligent control The design provides more options and interface
a maximum matching device matching: +1 two over-current release or loss of pressure release three over-current release latch +1
excellent performance and stable operation, long life and less maintenance
No explosion hazard, no pollution, low noise operation
Model Description:
CK VB 12 / T
25kA/31.5kA
Heat-stable short-circuit current rating
Rated Current 630A/1250A/1600A
Spring institutions
Rated voltage
Circuit Breaker
comking
Main technical parameters:
Name | Units | parameters | ||||
Rated voltage | kV | 12 | ||||
Rated insulation level | Rated short-term whithstand voltage | kV | 42 | |||
peakLightning Impulse whithstand voltage | kV | 75 | ||||
Rated Frequency | Hz | 50 | ||||
Secondary circuit voltage frequency tolerance | V | 2000 | ||||
Rated Current | A | 630 | 1250 | 1600 | ||
4sRated short-term whithstand current | kA | 25 | 25 | 31.5 | 31.5 | |
Rated peak current tolerance | kA | 63 | 63 | 80 | 80 | |
Rated short-circuit breaking current | kA | 25 | 25 | 31.5 | 31.5 | |
Rated short-circuit closing current | kA | 63 | 63 | 80 | 80 | |
Rated cable charging breaking current | A | 25 | ||||
Rated capacitor current portfolio Closing | kA | 12.5 | ||||
Rated a single / back-to-back capacitor bank breaking current | A | 630/400 | ||||
Mechanical life | Times | 20000 | ||||
Breaking number of rated current (electrical life) | Times | 20000 | ||||
number of Rated short-circuit current breaking | Times | 50 | ||||
clearance between open gap | mm | 11±1 | ||||
overtravel | mm | 3.5±1 | ||||
Average closing speed | m/s | 0.50.8 | ||||
Average opening speed | m/s | 0.91.2 | ||||
closing time | ms | 3570 | ||||
opening time | ms | 2050 | ||||
Arcing time | ms | ≤15 | ||||
Contact closing bounce time | ms | ≤2 | ||||
Three-phase contact line at different periods of gate
| ms | ≤2 | ||||
Dynamic and static contact allowed to wear a total thickness
| mm | 3 | ||||